The Effect of Osteotomy Dimension on Implant Insertion Torque, Healing Mode, and Osseointegration Indicators: A Study in Dogs
sds
By: Charles Marin, Estevam Bonfante, Rodrigo Granato, Rodrigo Neiva, Luiz Fernando Gil, Heloisa Fonseca, Marcelo Suzuki, Paulo G. Coelho
Effect of Simplified One-Step Drilling Protocol on Osseointegration
 
By: Arpita Patel, Luiz F. Gil,
Arthur Castellano, Gileade Freitas, Daniel Navarro, Ana P. Peredo, Nick Tovar, Paulo Coelho
Non-Washed Resorbable Blasting Media (NWRBM) on Titanium
Surfaces could Enhance Osteogenic Properties of MSCs
through Increase of miRNA-196a And VCAM1
 art23
By: Chiara Gardin, Letizia Ferroni, Adriano Piattelli, Stefano SIvolella, Barbara Zavan, Eitan Mijiritsky
Histomorphometry and Bone Mechanical Property Evolution Around Different Implant Systems at Early Healing Stages. An Experimental Study in Dogs
Histomorphometry_and_Bone_Mechanical_Property
By: Jimbo R, Anchieta R, Baldassarri M, Granato R, Marin C, Teixeira HS, Tovar N, Stefan V, Janal MN, Coelho PG
Full-Mouth Implant-Supported Rehabilitation with a Flapless Surgical Technique: a Treatment Approach Using Computer-Assisted Oral Implant Surgery
Full-Mouth-Implant-Supported-Rehabilitation
By: Mijiritsky E, Lorean A,Barbu H and Mazor Z
Effect of Implant Diameter on Reliability and Failure Modes of Molar Crowns
Effect-Of-Implant-Diameter-On-Reliability-And-Failure-Modes-Of-Molar-Crowns
By: Freitas-Junior AC, Bonfante EA, Martins LM, Silva NR, Marotta L, Coelho PG

 

Replacement of a Molar with 2 Narrow Diameter Dental Implants
Replacement-of-Molar-With-Two-NP-Implants
By: Mazor Z, Lorean A, Mijiritsky E, Levin L
Flapless Approach to Maxillary Sinus Augmentation Using Minimally Invasive Antral Membrane Balloon Elevation
Flapless-Approach-To-Maxillary-Sinus-Augmentation-Using-Minimally-Invasive-Antral-Membrane-Balloon-Elevation
By: Mazor Z, Kfir E, Lorean A, Mijiritsky E, Horowitz RA
Implant Diameter and Length Influence on Survival: Interim Results during the First 2 Years of Function of Implants by a Single Manufacturer
By: Mijiritsky E, Mazor Z, Lorean A, Levin L
Biomechanical and Histologic Evaluation of Non-Washed Resorbable Blasting Media and Alumina-Blasted/Acid-Etched Surfaces
Biomechanical-and-Histologic-Evaluation-of-Resorbable-Media-Vs-ABAE
By: Coelho PG, Marin C, Granato R, Giro G, Suzuki M, Bonfante EA

 

Nasal Floor Elevation Combined with Dental Implant Placement
Nasal-Floor-Elevation-Combined-With-Dental-Implant-Placement
By: Mazor Z, Lorean A, Mijiritsky E, Levin L

 

Plasma Treatment Maintains Surface Energy of the Implant Surface and Enhances Osseointegration
Plasma-Treatment-Maintains-Surface-Energy---Coelho(small)
By: Guastaldi FPS, Yoo D, Marin C, Jimbo R, Tovar N, Zanetta-Barbosa D, Coelho PG
Clinical and Radiological Evaluation of Two Stage Implant in a Single Stage Procedure and Two Stage Procedure – a Comparative Study
Clinical-and-Radiological-Evaluation-of-Two-Stage-Implant-In-A-Single-Stage-Procedure-and-Two-Stage-Procedure
By: Garg R, Borle RM, Datarkar AN

 

Loading...